flow rate Archives - Scentroid https://scentroid.com/wikiodour/tag/flow-rate/ Future of Sensory Technology Sat, 01 Feb 2020 17:20:50 +0000 en-CA hourly 1 https://wordpress.org/?v=6.9 https://scentroid.com/wp-content/uploads/2019/11/cropped-photo-1531834685032-c34bf0d84c77-32x32.jpg flow rate Archives - Scentroid https://scentroid.com/wikiodour/tag/flow-rate/ 32 32 Odour Abatement Efficiency https://scentroid.com/wikiodour/odour-abatement-efficiency/ Tue, 21 Jan 2020 13:49:28 +0000 http://gator4044.temp.domains/~scentroid/?post_type=epkb_post_type_1&p=12194 The reduction of the odour concentration or the odour flow rate due to an abatement technique

The post Odour Abatement Efficiency appeared first on Scentroid.

]]>
Overview

The reduction of the odour concentration or the odour flow rate due to an abatement technique expressed as a fraction (or percentage) of the odour concentration in or the odour flow rate of the untreated gas stream.

The post Odour Abatement Efficiency appeared first on Scentroid.

]]>
Dynamic Dilution https://scentroid.com/wikiodour/dynamic-dilution/ Mon, 20 Jan 2020 19:19:46 +0000 http://gator4044.temp.domains/~scentroid/?post_type=epkb_post_type_1&p=12143 Mixing of odorous gas and odour-neutral air measured by flow rate

The post Dynamic Dilution appeared first on Scentroid.

]]>
Overview

Mixing of odorous gas and odour-neutral air measured by flow rate. The consistent introduction of odour-free or odour-neutral air to a concentrated amount of an odorous gas allows for accurate measurement when determining the severity of the odour’s concentration and intensity.

The post Dynamic Dilution appeared first on Scentroid.

]]>
Specific Odour Emission Rate (SOER) https://scentroid.com/wikiodour/specific-odour-emission-rate-soer/ Mon, 20 Jan 2020 18:54:21 +0000 http://gator4044.temp.domains/~scentroid/?post_type=epkb_post_type_1&p=12125 Determines the odour concentration per time and area (flux)

The post Specific Odour Emission Rate (SOER) appeared first on Scentroid.

]]>
Overview

Determines the odour concentration per time and area (flux).  It is calculated by taking the product of the odour concentration and flow rate inside a sampling hood, divided by the area of the hood used to perform the measurement.  The area represents a ‘hood’ covering over the source such as a wind tunnel or static flux hood. 

Example

if a pond (passive area source) has an odour concentration after olfactometry analysis of 500OU/m3, the flow rate of neutral gas into the static flux hood was 2L/min (0.002m3/min) and the area of the static flux hood covering the surface is 0.6m2, then:
SOER = (500OU/m3 * 0.002m3/min)/0.6m2 = 1.67OU/m2/min

The post Specific Odour Emission Rate (SOER) appeared first on Scentroid.

]]>
Dilution Factor https://scentroid.com/wikiodour/dilution-factor/ Fri, 10 Jan 2020 17:34:53 +0000 http://gator4044.temp.domains/~scentroid/?post_type=epkb_post_type_1&p=12040 A ratio of diluting neutral gas to odorous sample gas.

The post Dilution Factor appeared first on Scentroid.

]]>
Overview

A ratio of diluting neutral gas to odorous sample gas.  According to ASTM E679, this is a ratio of diluting gas to the odour sample. According to EN13725, this is a ratio of the sum of the diluting gas and odour sample, to the odour sample.  It is calculated based on the flow rate.

Example

5 parts of diluting air to 1 part of sample

ASTM E679:  Diluting gas/odourous sample = 5:1 = 5

EN 13725:  (diluting gas + odourous sample)/odourous sample = 6:1 = 6